{"product_id":"castair-aftercooler-option-bundle-aoc2d-duplex-460v-complete-factory-options-package","title":"Castair Aftercooler Option Bundle AOC2D (Duplex) 460V - Complete Factory Options Package","description":"\u003cp\u003eThe \u003cstrong\u003eCastair Aftercooler Option Bundle AOC2D (Duplex) 460V\u003c\/strong\u003e is the complete factory-installed options package for Cast Air C2 duplex compressor systems wired for 460V three-phase power. A C2 duplex unit pairs two C2-series pumps on a shared tank — one active, one on standby — with automatic alternation and backup switching. This bundle provides all the aftercooler, drain, metering, and vibration management components factory-installed and rated for 460V duplex operation, at a 10% savings over individual option pricing.\u003c\/p\u003e\u003cp\u003eThe duplex configuration is specifically for operations that cannot tolerate compressor downtime. If one pump needs service, the second takes over automatically. The AOC2D-460 bundle ensures the entire system — not just the pumps — is properly equipped from day one.\u003c\/p\u003e\u003ch2\u003eWhat the AOC2D-460 Bundle Includes\u003c\/h2\u003e\u003ch3\u003eDual Aftercooler System\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eDual Belt Guard Aftercoolers (#BGAC1x2M):\u003c\/strong\u003e Two factory-mounted aftercoolers rated for 70 CFM total — matched to dual C2-series pump output. Cools both pump discharges before air reaches the shared tank and distribution system. Max operating pressure 250 PSIG, max inlet temperature 350°F. Achieves approximately 65% water vapor reduction.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eAutomatic Drain System\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir-Operated Auto Drain (#ADVSM):\u003c\/strong\u003e Purges condensate on each compressor cycle using discharge pressure. No separate power required. Full installation kit included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Auto Drain (#SDV03M):\u003c\/strong\u003e Timer-controlled 115V solenoid drain with strainer. Handles condensate purge during idle periods — overnight, weekends — when the compressor isn't cycling but condensate continues to accumulate.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHour Meter\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHour Meter (#HRM460M):\u003c\/strong\u003e 460V-rated elapsed time meter. In a duplex setup, tracking run hours on each pump separately allows you to balance maintenance intervals between the two heads and schedule service without losing production. One pump can come out for service while the other carries the load.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eDual Control\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eDual Control (#DC2):\u003c\/strong\u003e Start\/stop and constant-speed load\/unload modes for the duplex system. In high-demand facilities, constant-speed unloading reduces motor cycling and extends component life. In lighter-use periods, start\/stop saves energy.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eIntake Noise Silencers\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIntake Noise Silencers (#SA100x2M):\u003c\/strong\u003e Two silencers — one per pump head. A duplex installation means two pumps, two intake noise sources. Factory-mounted silencers address both without flow restriction.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eVibration Management\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eVibration Pads (#VP1004):\u003c\/strong\u003e Set of four heavy rubber isolation pads for the duplex installation. Two running pump-motor sets on a large shared tank generate significant vibration — isolation protects the floor, welds, and distribution piping.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eRight From Start Kit\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003e#RFS002:\u003c\/strong\u003e Cast Air startup kit for C2 pump family. Correct initial oil fill and break-in documentation for both pump heads.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eWho Needs the AOC2D-460 Bundle\u003c\/h2\u003e\u003cp\u003eThis bundle is for facilities installing a Cast Air C2 duplex compressor on 460V three-phase service. Common buyers: hospitals, manufacturing plants, commercial tire shops, and any operation where losing compressed air means shutting down production. The duplex provides genuine failover — not just a spare unit sitting in the corner, but automatic switchover if the primary pump faults or goes down for service.\u003c\/p\u003e\u003cp\u003eThe 460V requirement means you need three-phase 460V electrical service. If your facility runs 230V three-phase or single-phase, see the AOC2D (230V) bundle. Voltage mismatch destroys motors immediately.\u003c\/p\u003e\u003ch2\u003eSimplex vs. Duplex — The Decision\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplex AOC2 460V:\u003c\/strong\u003e One C2 pump. Lower cost. If it goes down, you're down. Fine for shops that can flex their schedule around maintenance windows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuplex AOC2D 460V (this product):\u003c\/strong\u003e Two C2 pumps. Automatic backup. Higher upfront investment, but zero planned downtime for pump maintenance. The right choice for production-critical environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC3 Duplex (AOC3D):\u003c\/strong\u003e If your CFM demand is higher than two C2 pumps can handle — roughly 70+ CFM at pressure — step up to the AOC3D bundle for C3 duplex systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 460V, three-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Compressor Family:\u003c\/strong\u003e Cast Air C2 duplex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAftercooler:\u003c\/strong\u003e #BGAC1x2M (dual), 70 CFM rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Operating Pressure:\u003c\/strong\u003e 250 PSIG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Inlet Air Temperature:\u003c\/strong\u003e 350°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHour Meter:\u003c\/strong\u003e #HRM460M (460V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Drain:\u003c\/strong\u003e Air-operated #ADVSM + Electronic #SDV03M (115V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Control:\u003c\/strong\u003e #DC2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntake Silencers:\u003c\/strong\u003e Two (#SA100x2M)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Pads:\u003c\/strong\u003e #VP1004 (set of 4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStartup Kit:\u003c\/strong\u003e #RFS002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBundle Savings:\u003c\/strong\u003e 10% off individual component pricing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\u003cp\u003eThe AOC2D-460 is factory-installed on your duplex compressor before it ships. All components are factory-mounted and tested. Contact us at 866-217-0063 or Cast Air at (320) 796-0851 for current pricing and lead times.\u003c\/p\u003e\u003ch3\u003eWhy Buy From OEM Diagnostic Tools?\u003c\/h3\u003e\u003cp\u003eWe've specialized in professional shop equipment since 2016. Free shipping, free pre-sale technical support at \u003cstrong\u003e866-217-0063\u003c\/strong\u003e, and full Cast Air manufacturer warranty. We'll confirm the right duplex bundle for your specific installation and electrical service before you order.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCall 866-217-0063 for quick answers and help!\u003c\/strong\u003e\u003c\/p\u003e","brand":"Cast Air","offers":[{"title":"Default Title","offer_id":53342515429589,"sku":"AOC2D-460","price":5035.32,"currency_code":"USD","in_stock":true}],"url":"https:\/\/aircompressorfactorydirect.com\/products\/castair-aftercooler-option-bundle-aoc2d-duplex-460v-complete-factory-options-package","provider":"Air Compressor Factory Direct","version":"1.0","type":"link"}