{"product_id":"castair-aftercooler-option-bundle-aoc1-460v-complete-factory-options-package","title":"Castair Aftercooler Option Bundle AOC1 460V - Complete Factory Options Package","description":"\u003cp\u003eThe \u003cstrong\u003eCastair Aftercooler Option Bundle AOC1-460\u003c\/strong\u003e is the \u003cstrong\u003e460-volt, three-phase\u003c\/strong\u003e version of Cast Air's factory aftercooler options package for simplex compressor installations. If your facility runs three-phase 460V electrical service — which is standard for higher-horsepower industrial compressor packages — the AOC1-460 is the correct bundle. The standard AOC1 (230V single-phase) and the AOC1-460 (460V three-phase) serve the same functional purpose but are wired and rated for different electrical services. Ordering the wrong voltage version is a real mistake that creates safety problems and requires a return — check your compressor motor nameplate for voltage and phase before ordering.\u003c\/p\u003e\n\n\u003cp\u003eThe aftercooler in this bundle is a fan-cooled heat exchanger that mounts in the compressor discharge line between the pump and the receiver tank. Compressor discharge air arrives at 250–350°F carrying a full moisture load. The aftercooler's job is to bring that air temperature down to within 15°F of ambient air temperature before it enters the tank — at that temperature, approximately 65% of the moisture load condenses and drains out at the aftercooler, not inside your tank and air lines. Shops running 460V three-phase service are typically running higher-horsepower compressors that produce larger volumes of hot air — getting aftercooling right at this scale has a proportionally larger impact on system air quality.\u003c\/p\u003e\n\n\u003ch2\u003eThree-Phase 460V Service: What It Means for Your Aftercooler Selection\u003c\/h2\u003e\n\u003cp\u003eThree-phase 460V electrical service is common in facilities with compressors in the 10 HP and above range, particularly in manufacturing, heavy fleet maintenance, and industrial operations. At this power level:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompressors run at higher sustained duty cycles and produce correspondingly larger volumes of hot discharge air\u003c\/li\u003e\n\u003cli\u003eThe moisture load entering the system per hour is greater — proper aftercooling at this scale matters more, not less\u003c\/li\u003e\n\u003cli\u003eThe fan motor and any electric controls in the aftercooler bundle must be rated for 460V three-phase — using a 230V component on 460V service is a safety hazard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AOC1-460 is built for this environment. The electrical components are rated for your service. The heat exchanger is matched to your compressor output. This is not a 230V unit with an adapter — it is the correct three-phase product.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features of the AOC1-460 Bundle\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e460V Three-Phase Configuration:\u003c\/strong\u003e All electrical components rated for 460V, three-phase power — correct for industrial facilities on standard three-phase service\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-Matched Components:\u003c\/strong\u003e Aftercooler sized and specified by Castair for the compressor models this bundle is designed for — not a field adaptation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e250 PSIG Maximum Working Pressure:\u003c\/strong\u003e Handles the full operating pressure range of all standard Castair industrial compressor models\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e350°F Maximum Inlet Air Temperature:\u003c\/strong\u003e Rated for the full discharge temperature range of industrial two-stage reciprocating and rotary screw pumps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCools to Within 15°F of Ambient:\u003c\/strong\u003e Brings compressed air from pump discharge temperature down to near ambient before the receiver tank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e65% Total Moisture Removal:\u003c\/strong\u003e Extracts approximately 65% of the water vapor load from the compressed air stream at the discharge point — every 20-degree temperature drop removes 50% of remaining moisture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Factory Package:\u003c\/strong\u003e All components for aftercooler installation in one bundle — aftercooler unit, fan assembly, drain provisions, and mounting hardware\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplex Configuration:\u003c\/strong\u003e For single-compressor installations — for duplex (two-compressor) systems, a different bundle is required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinnesota Manufacturing:\u003c\/strong\u003e Castair builds to industrial standards in Minnesota\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat Is Included in the AOC1-460 Bundle\u003c\/h2\u003e\n\u003cp\u003eThe AOC1-460 is a complete factory options package. Components are factory-matched to specific Castair compressor models — contact us to confirm the exact contents for your compressor before ordering.\u003c\/p\u003e\n\u003cp\u003eFactory bundle packages typically include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAftercooler heat exchanger:\u003c\/strong\u003e Fan-cooled, 250 PSIG \/ 350°F rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling fan and motor assembly:\u003c\/strong\u003e Rated for 460V, three-phase service\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate drain provisions:\u003c\/strong\u003e For removing moisture captured at the aftercooler\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and connection hardware:\u003c\/strong\u003e Factory-matched for the target compressor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional accessories available: filter with automatic drain, temperature control valve #86816.\u003c\/p\u003e\n\n\u003ch2\u003eAOC Bundle Configurations — Selecting the Right Version\u003c\/h2\u003e\n\u003cp\u003eThe AOC1 series covers three electrical and compressor configurations. Match your selection to your electrical service and compressor setup:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAOC1:\u003c\/strong\u003e 230V, single-phase, simplex — for standard single-phase shop and light commercial installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAOC1-460:\u003c\/strong\u003e 460V, three-phase, simplex — for industrial facilities on three-phase service \u003cem\u003e(this bundle)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAOC1D:\u003c\/strong\u003e 230V, single-phase, duplex — for two-compressor systems on single-phase service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not order across voltage configurations. The 230V and 460V versions are not interchangeable, and the electrical mismatch creates a safety hazard. If you are unsure which version matches your facility, call us — we will verify before anything ships.\u003c\/p\u003e\n\n\u003ch2\u003eFull Castair Free Standing Aftercooler Lineup (For Reference)\u003c\/h2\u003e\n\u003cp\u003eIf you are evaluating standalone aftercooler options in addition to the factory bundle, Castair's free standing series covers 35–300 CFM:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFSAC35:\u003c\/strong\u003e 35 CFM, 3\/4 inch NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFSAC50:\u003c\/strong\u003e 50 CFM, 1 inch NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFSAC75:\u003c\/strong\u003e 75 CFM, 1 inch NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFSAC100:\u003c\/strong\u003e 100 CFM, 1-1\/4 inch NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC120:\u003c\/strong\u003e 120 CFM, 1-1\/2 inch NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC150:\u003c\/strong\u003e 150 CFM, 1-1\/2 inch NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC240:\u003c\/strong\u003e 240 CFM, 2 inch NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC300:\u003c\/strong\u003e 300 CFM, 2 inch NPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll models: 250 PSIG maximum, 350°F maximum inlet, cools to within 15°F of ambient, 115V\/1-phase\/60 Hz fan power. The factory bundle (AOC1-460) integrates the aftercooler with 460V three-phase electrical components for your specific compressor.\u003c\/p\u003e\n\n\u003ch2\u003eWhen Does a Facility Need the AOC1-460?\u003c\/h2\u003e\n\u003cp\u003eThe AOC1-460 is for facilities that:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperate on 460V three-phase service\u003c\/strong\u003e with Castair compressors that specify this bundle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAre purchasing a new Castair industrial compressor\u003c\/strong\u003e on three-phase service and want factory aftercooler integration from day one\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAre retrofitting aftercooling\u003c\/strong\u003e to an existing Castair three-phase installation and need factory-matched components rather than a field-assembled solution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHave moisture quality problems at industrial scale\u003c\/strong\u003e — high-horsepower compressors produce proportionally more hot, wet air, and aftercooling is even more critical at this output level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun spray finishing, precision machining, or pneumatic automation\u003c\/strong\u003e where moisture in the air line creates direct production defects or equipment damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor 230V single-phase installations, order the AOC1. For duplex systems, order the AOC1D.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e AOC1-460\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Castair (Cast Air) — Minnesota, USA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBundle Type:\u003c\/strong\u003e Complete factory aftercooler options package\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 460V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Configuration:\u003c\/strong\u003e Simplex (single compressor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 250 PSIG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inlet Air Temperature:\u003c\/strong\u003e 350°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproach Temperature:\u003c\/strong\u003e Within 15°F of ambient\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Removal:\u003c\/strong\u003e Approximately 65% of total moisture (at 250°F inlet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Accessories — Aftercoolers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Contact us to confirm matched Castair compressor models\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy Buy From Air Compressor Factory Direct?\u003c\/h2\u003e\n\u003cp\u003eAir Compressor Factory Direct has been supplying commercial and industrial compressed air equipment since 2016. We carry the full Castair line — compressors, aftercoolers, factory option bundles, and accessories. When you are buying an aftercooler bundle for a three-phase industrial installation, getting the voltage and configuration right before the order ships matters. We verify before anything leaves the warehouse.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree Shipping:\u003c\/strong\u003e AOC1-460 bundles ship free to the continental US\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree Pre-Sale Technical Support:\u003c\/strong\u003e Call us with your compressor model number and electrical service — we will confirm the right bundle version before you order\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Manufacturer Warranty:\u003c\/strong\u003e All Castair equipment and factory option bundles carry full factory warranty\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHonest Guidance:\u003c\/strong\u003e If the AOC1-460 is not the right fit for your installation, we will tell you which bundle is and why\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCastair Specialist:\u003c\/strong\u003e We know the full product line and can answer technical questions specific to Castair compressor models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCall 866-217-0063 for quick answers and help!\u003c\/strong\u003e\u003c\/p\u003e","brand":"Cast Air","offers":[{"title":"Default Title","offer_id":53342514348245,"sku":"AOC1-460","price":2192.48,"currency_code":"USD","in_stock":true}],"url":"https:\/\/aircompressorfactorydirect.com\/products\/castair-aftercooler-option-bundle-aoc1-460v-complete-factory-options-package","provider":"Air Compressor Factory Direct","version":"1.0","type":"link"}