{"product_id":"castair-60-gallon-vertical-air-receiver-tank-150psi-60v150","title":"Castair 60 Gallon Vertical Air Receiver Tank 150PSI 60V150","description":"\u003ch2\u003eCastair 60 Gallon Vertical Air Receiver Tank — 150 PSI, ASME-Coded (Part# 60V150)\u003c\/h2\u003e\n\n\u003cp\u003eThe Castair 60V150 is a 60-gallon vertical air receiver tank built to ASME code standards, rated to 150 PSI. It is a power-coded tank — meaning it carries the ASME certification required for commercial and industrial installations in most jurisdictions. If you are building or upgrading a compressor system and need a tank that will pass an insurance inspection or meet a local code requirement, this is the spec that matters.\u003c\/p\u003e\n\n\u003cp\u003eAt 20 inches in diameter and 48 inches tall, this tank fits where a lot of 60-gallon horizontals will not — it has a small floor footprint and works well in tighter machine rooms or against a wall. The vertical orientation also makes it easier to drain condensate from the bottom port without having to work around legs or a saddle mount.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 60V150\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 60 gallons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter x Height:\u003c\/strong\u003e 20\" x 48\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Plate:\u003c\/strong\u003e 9.5\" x 25\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 150 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 138 lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ASME-coded (power coded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat ASME-Coded Means and Why It Matters\u003c\/h3\u003e\n\u003cp\u003eASME Section VIII governs unfired pressure vessels, including air receiver tanks. An ASME-coded tank has been built and inspected to a documented standard — wall thickness, weld quality, relief valve sizing, and pressure testing are all verified. For commercial shops, this matters for several reasons:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsurance:\u003c\/strong\u003e Many commercial property insurers require ASME-coded pressure vessels. A non-code tank can void coverage if it fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal code compliance:\u003c\/strong\u003e Many states and municipalities require ASME certification for tanks above a certain pressure or volume threshold in commercial settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResale and inspection:\u003c\/strong\u003e ASME-coded tanks have a data plate that inspectors can verify. Non-code tanks do not.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you are building a system for a commercial shop, an automotive dealer, a manufacturing facility, or any location that carries general liability insurance, specify ASME-coded tanks from the start. Retrofitting compliance after the fact is expensive.\u003c\/p\u003e\n\n\u003ch3\u003eCastair Tank Lineup — Finding the Right Size\u003c\/h3\u003e\n\u003cp\u003eCastair offers both ASME-coded and non-code tanks across a range of sizes. Here is the full picture:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e60V150 (this tank):\u003c\/strong\u003e 60 gal, vertical, 20x48\", 150 PSI, 138 lbs — ASME coded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e80V200:\u003c\/strong\u003e 80 gal, vertical, 24x48\", 200 PSI, 230 lbs — ASME coded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e80H200:\u003c\/strong\u003e 80 gal, horizontal, 20x66\", 200 PSI, 230 lbs — ASME coded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8P150D:\u003c\/strong\u003e 8 gal, DD portable, 10x24\", 150 PSI, 30 lbs — non-code\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8P150B:\u003c\/strong\u003e 8 gal, BD portable, 10x24\", 150 PSI, 35 lbs — non-code\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8TT150N:\u003c\/strong\u003e 8 gal, twin tank, 17x34\", 150 PSI, 68 lbs — non-code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 60V150 is rated to 150 PSI. If your system runs at higher pressures — particularly two-stage systems that deliver 175 PSI or higher — step up to the 80V200 (200 PSI rated). A tank rated at 150 PSI should not be used on a system that regularly operates above that working pressure.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop plate:\u003c\/strong\u003e The 9.5x25\" top plate provides the mounting surface for your compressor pump and motor assembly. Verify your pump base dimensions against this plate before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical installation:\u003c\/strong\u003e Requires a level surface. The tank should be secured to prevent tipping — particularly important in seismic zones or on smooth concrete floors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate drain:\u003c\/strong\u003e Install a manual or automatic drain valve at the bottom port. Vertical tanks are straightforward to drain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelief valve:\u003c\/strong\u003e The tank requires a properly sized ASME relief valve. The relief valve must be rated at or below the tank's maximum allowable working pressure (150 PSI here).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e At 138 lbs empty, the 60V150 requires two people or mechanical assistance to position. Plan your installation accordingly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen This Tank Fits Your Application\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-phase or three-phase systems running at 150 PSI or below\u003c\/li\u003e\n\u003cli\u003eLight-to-medium duty shop compressors (5 HP to 10 HP range is typical for 60-gallon tanks)\u003c\/li\u003e\n\u003cli\u003eInstallations where vertical orientation is preferred for space reasons\u003c\/li\u003e\n\u003cli\u003eAny application requiring ASME certification — commercial shops, dealerships, light industrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen to Step Up\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIf your system operates above 150 PSI working pressure, move to the 80V200 (200 PSI rated)\u003c\/li\u003e\n\u003cli\u003eIf your shop demand is high and you are running a larger pump (15 HP or above), a 60-gallon tank will short-cycle the compressor. Consider the 80-gallon options.\u003c\/li\u003e\n\u003cli\u003eIf you need horizontal orientation for installation under a workbench or in a low-clearance area, the 80H200 is the horizontal option in the Castair coded lineup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Buy From Air Compressor Factory Direct?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCastair specialist:\u003c\/strong\u003e We stock Castair tanks and know the product line. If you need to verify top plate dimensions against your existing pump, call us.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree shipping\u003c\/strong\u003e on qualifying orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree technical support:\u003c\/strong\u003e 866-217-0063 — we can help you select the right tank size and pressure rating for your system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Castair components:\u003c\/strong\u003e ASME data plate included as built. Not an aftermarket or import tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHonest sizing guidance:\u003c\/strong\u003e We will tell you if the 60-gallon is undersized for your application rather than just take the order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCall 866-217-0063 for quick answers and help!\u003c\/strong\u003e\u003c\/p\u003e","brand":"Cast Air","offers":[{"title":"Default Title","offer_id":53342509924565,"sku":"60V150","price":1268.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/8466\/0949\/files\/Castair_Vertical_Air_Receiver_0fe91fe5-1cd5-4257-a36e-5835ee5158b5.png?v=1772652540","url":"https:\/\/aircompressorfactorydirect.com\/products\/castair-60-gallon-vertical-air-receiver-tank-150psi-60v150","provider":"Air Compressor Factory Direct","version":"1.0","type":"link"}