{"product_id":"castair-3-4-female-npt-3-4-npt-f-outlet-vent-outlet-1-2-npt-50-max-cfm-electric-dual-3-way-pilot-valve-gas-engine-nlg-7","title":"Castair 3\/4\" Female NPT 3\/4\" NPT-F Outlet Vent Outlet 1\/2\" NPT 50 Max. CFM Electric Dual 3 Way Pilot Valve Gas engine NLG-7","description":"\u003ch2\u003eCastair NLG-7 Three-Way Pilot Valve — 3\/4\" Compression\/NPT Gas Engine, 50 CFM\u003c\/h2\u003e\n\n\u003cp\u003eThe Castair NLG-7 is a three-way pilot valve for gas engine-driven air compressors requiring 50 CFM flow capacity at the control valve. It uses a 3\/4\" male compression inlet and a 3\/4\" male NPT outlet, with a 1\/2\" NPT vent port for pressure exhaust on unload. At $324.94, it is Castair's high-capacity gas engine pilot valve — the mechanical counterpart to the NLDC-1 (which is solenoid-operated for electric dual systems). If your shop runs a large gas engine-driven compressor with high-capacity control lines and the existing 25 CFM valves are causing pressure drop or erratic cycling, the NLG-7 is the correct upgrade.\u003c\/p\u003e\n\n\u003cp\u003eBefore ordering, confirm: your compressor is gas engine-driven (continuous engine run, mechanically unloaded — not electric motor start\/stop), the control circuit flow demand is in the 50 CFM range or you have experienced failures with smaller valves, and your plumbing matches the NLG-7's port configuration (3\/4\" compression on inlet, 3\/4\" NPT on outlet, 1\/2\" NPT on vent). The combination of compression inlet and NPT outlet is unusual and specific — it matches original equipment plumbing on certain engine-driven compressor configurations where compression tubing is used on the tank\/discharge side and threaded pipe is used on the unloader side.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the NLG-7 Does in the Control System\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Flow Load\/Unload Control:\u003c\/strong\u003e The NLG-7 manages the compressor head's load state for large gas engine-driven units. When tank pressure reaches cut-out, the valve shifts and vents the unloader line — the compressor head unloads while the engine continues running at governed speed. When pressure drops to cut-in, the valve shifts back and the head reloads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThree-Way Function:\u003c\/strong\u003e Three ports, three states — inlet to outlet (loaded), outlet to vent (unloaded), vent closed (loaded). The 1\/2\" NPT vent port is large enough to exhaust the higher volume of trapped pressure in a 50 CFM system quickly, preventing sluggish unload response.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePneumatic Mechanical Operation:\u003c\/strong\u003e No solenoid, no electrical connections. The NLG-7 responds to pneumatic pilot pressure derived from the tank or discharge line. The pilot pressure signal shifts the valve spool — no wiring, no coil, no electrical components to fail due to vibration, moisture, or voltage problems common in outdoor engine-driven applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e50 CFM Capacity:\u003c\/strong\u003e Double the capacity of the NG-1 and NG-18. For large single-stage or two-stage gas engine-driven compressors where the control circuit carries significant air volume, the NLG-7 handles the flow without the restriction that causes pressure drop and erratic cycling on smaller valves.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMixed Connection Style — Compression Inlet, NPT Outlet:\u003c\/strong\u003e The 3\/4\" male compression inlet and 3\/4\" male NPT outlet reflect the original plumbing configuration of specific engine-driven compressor designs. The compression inlet connects to compression-style tubing from the tank\/discharge; the NPT outlet connects to threaded pipe going to the unloader mechanism.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePort Configuration and Plumbing\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInlet:\u003c\/strong\u003e 3\/4\" male compression — this is a male compression fitting; it connects into a female compression fitting on the control line. Confirm whether your existing inlet fitting is male or female compression before ordering.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutlet:\u003c\/strong\u003e 3\/4\" male NPT — connects to a female NPT threaded fitting on the unloader mechanism or control line\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVent Outlet:\u003c\/strong\u003e 1\/2\" NPT — exhausts trapped pressure on unload; this larger vent port accommodates the higher exhaust volume of a 50 CFM system. Use a 1\/2\" NPT muffler to reduce noise if the compressor operates in an enclosed space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePilot Ports:\u003c\/strong\u003e 1\/8\" female NPT — pneumatic pilot pressure input for valve actuation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePSI Range Options:\u003c\/strong\u003e Suffix 100 for 100–120 PSI systems; suffix 140 for 140–170 PSI systems. Order NLG-7100 or NLG-7140. The internal spring calibration is specific to the pressure range — the wrong suffix means the valve cycles at the wrong pressure, causing early cut-in or late unloading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eUnderstanding the Compression + NPT Mixed Port Configuration\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhy This Combination Exists:\u003c\/strong\u003e Certain gas engine-driven compressor manufacturers ran compression tubing from the tank\/discharge to the pilot valve inlet (for flexible routing and vibration tolerance) but used threaded NPT pipe connections on the unloader side of the circuit (for secure, rigid connections near the cylinder head). The NLG-7 matches this original equipment plumbing pattern.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMale Compression Inlet:\u003c\/strong\u003e The 3\/4\" male compression fitting on the NLG-7 has a hex body that accepts a nut and ferrule from the compression tubing line. The tubing slides over the male fitting body, the ferrule seats, and the nut compresses the ferrule to seal. Do not confuse male and female compression fittings — they do not interchange.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMale NPT Outlet:\u003c\/strong\u003e The 3\/4\" male NPT outlet screws into a female NPT fitting on the unloader line or mechanism. Standard NPT taper thread with thread sealant. This is a rigid, pipe-style connection — appropriate for the unloader side where stability matters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMixed vs. All-NPT Systems:\u003c\/strong\u003e If both your inlet and outlet lines are 3\/4\" NPT (all threaded pipe), the correct valve is the NLDC-1 for electric dual systems — but the NLG-7 has no direct all-NPT gas engine equivalent at 50 CFM in the current Castair lineup. Call us to confirm the correct part for your specific plumbing configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow a Three-Way Pilot Valve Works\u003c\/h3\u003e\n\u003cp\u003eA three-way pilot valve controls the loaded and unloaded states of a gas engine compressor head using three flow ports. In loaded operation, the valve spool holds the inlet-to-outlet path open: the pneumatic control signal passes from the tank through the NLG-7 to the unloader mechanism, keeping the compressor head engaged in full compression. The gas engine runs at governed speed and the compressor delivers air to the tank.\u003c\/p\u003e\n\n\u003cp\u003eWhen tank pressure reaches the cut-out threshold, the pneumatic pilot signal pressure is sufficient to overcome the valve spool spring and shift the spool. The inlet closes and the outlet connects to the 1\/2\" NPT vent port. The trapped pressure in the unloader line exhausts through the vent, the unloader mechanism opens, and the compressor head runs free (unloaded) while the engine continues running. When the tank pressure drops to cut-in, the pilot signal pressure drops below the spring force, the spool shifts back, the vent closes, and the outlet re-pressurizes from the inlet. The unloader closes and compression resumes. This mechanical cycling continues for the life of the valve without any electrical components involved.\u003c\/p\u003e\n\n\u003ch3\u003eGas Engine Compressor Control — Practical Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngine Continues Running:\u003c\/strong\u003e In a gas engine system, the engine does not stop at cut-out pressure. It runs at a set governed speed continuously. The pilot valve's job is to unload the compressor head so the engine is not fighting full compression when the tank is full. Proper unloading protects the engine from unnecessary load during idle periods.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration Environment:\u003c\/strong\u003e Gas engine compressors vibrate more than electric motor-driven units. The NLG-7's pneumatic mechanical operation has no coil or solenoid components to loosen or fail from vibration. However, the compression inlet fitting and NPT outlet connections should be checked for tightness periodically in high-vibration applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutdoor and Remote Site Use:\u003c\/strong\u003e Many gas engine compressors operate outdoors or at remote sites where electrical reliability is a concern. The NLG-7's purely mechanical operation is an advantage here — there is no solenoid to corrode, no wiring to damage, and no coil voltage requirement to match.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePilot Line Routing:\u003c\/strong\u003e The 1\/8\" female NPT pilot ports connect to the pneumatic pilot line that carries the signal pressure from the tank pressure tap. Keep this line as short and direct as possible — long, convoluted pilot lines can cause delayed valve response, particularly on larger systems where the volume of pilot line itself slows signal propagation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePilot Valve Selection Guide — Complete Castair Lineup\u003c\/h3\u003e\n\u003cp\u003eConfirm the NLG-7 is correct for your application, or identify the right alternative:\u003c\/p\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePart #\u003c\/th\u003e\n      \u003cth\u003eType\u003c\/th\u003e\n      \u003cth\u003eInlet\u003c\/th\u003e\n      \u003cth\u003eOutlet\u003c\/th\u003e\n      \u003cth\u003eVent\u003c\/th\u003e\n      \u003cth\u003eMax CFM\u003c\/th\u003e\n      \u003cth\u003eApplication\u003c\/th\u003e\n      \u003cth\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eD2M\u003c\/td\u003e\n\u003ctd\u003e1-way\u003c\/td\u003e\n\u003ctd\u003e1\/4\" F NPT\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eDirect w\/felt\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eGas or Electric\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBG2-M\u003c\/td\u003e\n\u003ctd\u003e2-way\u003c\/td\u003e\n\u003ctd\u003e1\/4\" F NPT\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eDirect w\/felt\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eGas engine\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBE2-M\u003c\/td\u003e\n\u003ctd\u003e2-way\u003c\/td\u003e\n\u003ctd\u003e1\/4\" F NPT\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eDirect w\/felt\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eElectric dual\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBLG\u003c\/td\u003e\n\u003ctd\u003e2-way\u003c\/td\u003e\n\u003ctd\u003e1\/2\" F NPT\u003c\/td\u003e\n\u003ctd\u003e1\/2\" F NPT\u003c\/td\u003e\n\u003ctd\u003e1\/4\" F NPT pilot\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003eGas engine\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBLE\u003c\/td\u003e\n\u003ctd\u003e2-way\u003c\/td\u003e\n\u003ctd\u003e1\/2\" F NPT\u003c\/td\u003e\n\u003ctd\u003e1\/2\" F NPT\u003c\/td\u003e\n\u003ctd\u003e1\/4\" F NPT pilot\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003eElectric dual\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNDC-1\u003c\/td\u003e\n\u003ctd\u003e3-way\u003c\/td\u003e\n\u003ctd\u003e1\/2\" F NPT\u003c\/td\u003e\n\u003ctd\u003e1\/2\" F NPT\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003eElectric dual\u003c\/td\u003e\n\u003ctd\u003e$110.11\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNG-1\u003c\/td\u003e\n\u003ctd\u003e3-way\u003c\/td\u003e\n\u003ctd\u003e1\/2\" F NPT\u003c\/td\u003e\n\u003ctd\u003e1\/2\" F NPT\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003eGas engine\u003c\/td\u003e\n\u003ctd\u003e$115.50\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNG-18\u003c\/td\u003e\n\u003ctd\u003e3-way\u003c\/td\u003e\n\u003ctd\u003e3\/4\" compression\u003c\/td\u003e\n\u003ctd\u003e1\/2\" F NPT\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003eGas engine\u003c\/td\u003e\n\u003ctd\u003e$115.50\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNLDC-1\u003c\/td\u003e\n\u003ctd\u003e3-way\u003c\/td\u003e\n\u003ctd\u003e3\/4\" F NPT\u003c\/td\u003e\n\u003ctd\u003e3\/4\" F NPT\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPT\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eElectric dual\u003c\/td\u003e\n\u003ctd\u003e$324.94\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNLG-7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3-way\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4\" male comp.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4\" male NPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2\" NPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGas engine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e$324.94\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003ePSI Suffix:\u003c\/strong\u003e Add 100 (100–120 PSI) or 140 (140–170 PSI) when ordering. Example: NLG-7100 or NLG-7140.\u003c\/p\u003e\n\n\u003ch3\u003eWhen Does a Shop Need the NLG-7 vs. Alternatives\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNLG-7 is right when:\u003c\/strong\u003e You have a large gas engine-driven compressor with a 3\/4\" male compression inlet and 3\/4\" male NPT outlet on the control circuit, operating at 50 CFM or where smaller valves have caused pressure drop or erratic cycling. It is also the correct replacement when the original NLG-7 has failed and existing plumbing is intact.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStep down to NG-1 or NG-18 when:\u003c\/strong\u003e Your gas engine compressor operates at 25 CFM or less at the valve. The NG-1 (1\/2\" NPT inlet and outlet, $115.50) and NG-18 (3\/4\" compression inlet, 1\/2\" NPT outlet, $115.50) are less expensive and sufficient for smaller systems. Do not oversize unless the system actually demands it.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUse NLDC-1 when:\u003c\/strong\u003e Your compressor is electric motor-driven, not gas engine. The NLDC-1 has similar 50 CFM capacity and 3\/4\" NPT connections but uses a solenoid for electric dual control. It is the same price ($324.94) but fundamentally different in operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConsider BLG when:\u003c\/strong\u003e Your gas engine system uses a 2-way pilot function at higher CFM (BLG is rated to 60 CFM) with 1\/2\" NPT connections. Different valve function and vent configuration — confirm your control circuit design before substituting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDo not substitute a 25 CFM valve on a 50 CFM system:\u003c\/strong\u003e Undersizing forces the valve to operate near its limit, causing measurable pressure drop across the valve body. In a load\/unload control circuit, this manifests as sluggish unloading, excessive on\/off cycling, and accelerated wear on the unloader mechanism and motor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e NLG-7\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eValve Type:\u003c\/strong\u003e 3-way pilot valve\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas engine-driven air compressor control systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Pneumatically actuated (no solenoid)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInlet Port:\u003c\/strong\u003e 3\/4\" male compression\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutlet Port:\u003c\/strong\u003e 3\/4\" male NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVent Outlet Port:\u003c\/strong\u003e 1\/2\" NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePilot Ports:\u003c\/strong\u003e 1\/8\" female NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Flow Capacity:\u003c\/strong\u003e 50 CFM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Range Options:\u003c\/strong\u003e 100–120 PSI (order as NLG-7100) or 140–170 PSI (order as NLG-7140)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Castair\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrice:\u003c\/strong\u003e $324.94\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Buy From Air Compressor Factory Direct?\u003c\/h3\u003e\n\u003cp\u003eAir Compressor Factory Direct has specialized in air compressor controls and replacement parts since 2016. The NLG-7 is a specific-application valve — the mixed compression\/NPT port configuration and gas engine designation mean it is easy to order the wrong part if you are matching by size alone. When you call us, we will confirm the valve type, port configuration, and pressure range for your compressor before anything ships.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFree Shipping:\u003c\/strong\u003e All orders ship free. No handling fees, no minimums.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFree Tech Support:\u003c\/strong\u003e Call 866-217-0063 to confirm whether the NLG-7 matches your compressor's plumbing and drive type, and which pressure suffix to order. For a $324.94 part, it is worth the call.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull Manufacturer Warranty:\u003c\/strong\u003e Every Castair valve we sell carries the full manufacturer warranty. No grey-market inventory, no refurbished parts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrect Part, First Time:\u003c\/strong\u003e The NLG-7 and NLDC-1 are the same price but serve completely different applications. We will make sure you have the right one before we charge your card.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCall 866-217-0063 for quick answers and help!\u003c\/strong\u003e\u003c\/p\u003e","brand":"Cast Air","offers":[{"title":"Default Title","offer_id":53342572740821,"sku":"NLG-7","price":599.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/8466\/0949\/files\/PILOT-VALVES-2-180x300.jpg?v=1772652752","url":"https:\/\/aircompressorfactorydirect.com\/products\/castair-3-4-female-npt-3-4-npt-f-outlet-vent-outlet-1-2-npt-50-max-cfm-electric-dual-3-way-pilot-valve-gas-engine-nlg-7","provider":"Air Compressor Factory Direct","version":"1.0","type":"link"}