{"product_id":"castair-15-hp-3phase-rotary-screw-air-compressor-58-cfm-at-100-psi-120-gal-horiz-tank-460-r15312hg30","title":"Castair 15 HP 3Phase Rotary Screw Air Compressor 58 cfm at 100 psi 120 Gal Horiz Tank 460 R15312HG30","description":"\u003ch2\u003eCast Air 15 HP 460V 3-Phase Rotary Screw Air Compressor â€” 58 CFM at 100 PSI, 120-Gallon Horizontal Tank\u003c\/h2\u003e\n\n\u003cp\u003eThis is the unit you look at when your 10HP compressor can no longer keep up. The Cast Air R15312HG30-460 is a 15 horsepower rotary screw compressor running on 460V 3-phase power, delivering 58 CFM at 100 PSI with a 120-gallon horizontal storage tank. It is built for production environments where air demand is continuous and downtime is not an option.\u003c\/p\u003e\n\n\u003cp\u003eThe 460V voltage rating matters for installation planning. At 460V 3-phase, the amperage draw is roughly half what a 230V unit of the same horsepower requires. That means smaller wire runs, lighter breaker sizing, and less heat in your electrical panel. If your facility already has 460V 3-phase service â€” common in shops that run CNC equipment, large lifts, or industrial spray booths â€” this unit integrates without an electrician having to upsize your panel.\u003c\/p\u003e\n\n\u003ch3\u003ePerformance: What 58 CFM Actually Gets You\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual spray guns simultaneously:\u003c\/strong\u003e A high-volume low-pressure (HVLP) spray gun typically draws 12â€“18 CFM at the gun. Two painters working at the same time puts you at 24â€“36 CFM. This unit has 22+ CFM of headroom above that at 100 PSI.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eImpact wrenches:\u003c\/strong\u003e A 1\/2\" impact draws 4â€“5 CFM. A 3\/4\" or 1\" impact draws 7â€“12 CFM. At 58 CFM, you can run three or four impact wrenches simultaneously with air to spare for other tooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir-powered lifts and tools together:\u003c\/strong\u003e Running an air-powered two-post lift (typically 10â€“20 CFM while raising\/lowering) alongside active tool use is feasible with this output. The 120-gallon tank provides buffer storage so short peaks don't cause pressure drops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSustained operation:\u003c\/strong\u003e Rotary screw compressors are designed for 100% duty cycle. Unlike reciprocating (piston) compressors that need rest cycles, this unit can run continuously without overheating or premature wear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e120-Gallon Horizontal Tank Configuration\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage capacity:\u003c\/strong\u003e 120 gallons of compressed air at system pressure. Larger tank volume means the compressor cycles less frequently and handles short burst demand from multiple tools without hunting for pressure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHorizontal orientation:\u003c\/strong\u003e The horizontal tank sits low to the ground with a stable footprint. Plumbing connections on a horizontal tank are typically more accessible â€” you can tap drain valves, supply lines, and secondary drops along the tank length without working at height.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFloor mounting:\u003c\/strong\u003e The horizontal configuration gives you a lower center of gravity. Less concern about stability in environments with fork traffic or floor vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondensate drainage:\u003c\/strong\u003e Horizontal tanks accumulate condensate along the bottom of the tank. A properly positioned auto-drain or manual drain valve addresses this. Install at the lowest point of the tank end.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRotary Screw Technology vs. Piston Compressors\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuous duty:\u003c\/strong\u003e Rotary screw units compress air through two interlocking helical rotors. There are no pistons, no connecting rods, no valve plates wearing out. Designed for continuous operation at rated output.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower noise:\u003c\/strong\u003e Rotary screw compressors run significantly quieter than reciprocating units of the same output. Important in shop environments where communication and phone calls happen near the compressor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil-injected cooling:\u003c\/strong\u003e Oil circulates through the compression chamber, cooling the rotors and sealing rotor clearances. This keeps discharge temperatures low and extends component life. The oil is separated from the compressed air before it reaches your tools.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaintenance interval:\u003c\/strong\u003e Routine maintenance on rotary screw units is typically oil changes, oil filter replacement, air\/oil separator element, and intake filter â€” at intervals specified in the service manual. Not the daily oiling and ring inspection cycles of a piston unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhere This Unit Fits in the Lineup\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBelow this (10HP range):\u003c\/strong\u003e A 10HP rotary screw delivers approximately 35â€“42 CFM at 100 PSI. If your shop consistently runs at 70â€“80% of that capacity, you are a cycle or two away from pressure-related slowdowns during peak demand. That's when the 15HP is the right step up.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThis unit (15HP, 58 CFM):\u003c\/strong\u003e R15312HG30-460. Production body shops, fleet service facilities with multiple bays active simultaneously, shops running spray painting alongside heavy tool use.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAbove this (20HP+):\u003c\/strong\u003e If you are running a full collision center with a dedicated prep area, paint booth, and multiple active bays simultaneously, or if you have frame equipment and alignment racks pulling air at the same time, 20HP and above becomes the appropriate range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e230V version:\u003c\/strong\u003e The R15312HG30-230 is the same unit wired for 230V 3-phase. Choose based on your available shop voltage. If you have both services available, 460V is generally the better choice for reduced wire and breaker sizing at this horsepower level.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Considerations\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical service:\u003c\/strong\u003e 460V 3-phase is required. Confirm your panel has the correct voltage and available amperage before ordering. Consult a licensed electrician for the final circuit sizing based on your specific run length and local code requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Rotary screw compressors generate heat. The compressor room needs adequate airflow â€” typically the unit specification will call out minimum cubic feet per minute of room air exchange. Inadequate ventilation causes thermal shutdown and shortened component life.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir line plumbing:\u003c\/strong\u003e At 58 CFM output, use appropriately sized supply lines. Undersized piping creates pressure drop between the compressor and your tools. General guideline: 3\/4\" or 1\" supply main for runs under 100 feet at this CFM level.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondensate management:\u003c\/strong\u003e Run a refrigerated air dryer downstream of the compressor if you are painting or running air tools sensitive to moisture. A desiccant dryer may be appropriate for paint work demanding very low dew points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Specifications\u003c\/h3\u003e\n\u003cp\u003eDetailed specifications including exact motor frame, discharge temperature, oil capacity, inlet size, full-load amps at 460V, weight, and exact footprint dimensions are available on request. Contact us with your application details and we can provide the complete spec sheet.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Buy From OEM Diagnostic Tools?\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecialist since 2016:\u003c\/strong\u003e We focus on professional shop equipment. We know the product lines, the installation requirements, and the real-world performance of the units we sell.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFree shipping:\u003c\/strong\u003e This unit ships free to commercial addresses in the continental US.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFree tech support:\u003c\/strong\u003e Call us at 866-217-0063 before and after your purchase. We can help you size your electrical service, plan your air distribution, and troubleshoot issues after installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull manufacturer warranty:\u003c\/strong\u003e Backed by Cast Air's warranty. We handle the process if you have a warranty claim.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHonest guidance:\u003c\/strong\u003e If the 15HP is more than you need, we'll tell you. If your application needs 20HP, we'll tell you that too. We'd rather you order the right unit than the wrong one.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCall 866-217-0063 for quick answers and help!\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"product-faq\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is the duty cycle on the R15312HG30-460, and how does that compare to a reciprocating piston compressor?\u003c\/h3\u003e\n\u003cp\u003eThe R15312HG30-460 is rated for 100% continuous duty — it can run indefinitely without a mandatory cool-down period. A piston compressor typically runs at 60–75% duty cycle, meaning it needs to rest roughly 15–24 minutes out of every hour under sustained load. If your shop runs air tools, lifts, or spray equipment for extended shifts, the rotary screw design on this unit eliminates the production interruptions and heat buildup that come with reciprocating machines at that workload.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat CFM output does this unit produce, and what tools or equipment can it support simultaneously?\u003c\/h3\u003e\n\u003cp\u003eThe R15312HG30-460 delivers approximately 50–54 CFM at 125 PSI from its 15 HP Cast Air rotary screw end. That output is sufficient to run multiple impact wrenches, a continuous-duty sandblast cabinet, plasma cutter air supply, or several DA sanders at the same time — depending on individual tool demand. For reference, a 1\/2\" impact wrench typically draws 4–5 CFM, so this unit has enough headroom to serve a busy multi-bay shop or light production line without pressure drop issues.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat electrical service does the R15312HG30-460 require, and what breaker size do I need?\u003c\/h3\u003e\n\u003cp\u003eThis unit runs on 460V, 3-phase power and draws approximately 21–23 FLA (full load amps) at that voltage. NEC requires a disconnect and breaker sized at 125% of FLA for motor branch circuits, so you'll want a 30-amp breaker minimum — verify with your electrician against your local code and actual wire run length. The 460V configuration is the most efficient option for 3-phase installs; it reduces current draw and allows smaller wire gauge compared to a 208\/230V 3-phase setup at the same horsepower.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat are the oil change intervals for the rotary screw end on this Cast Air unit?\u003c\/h3\u003e\n\u003cp\u003eCast Air rotary screw compressors use compressor-grade synthetic lubricant with a typical service interval of 2,000–4,000 hours depending on operating environment — dusty or hot conditions call for the shorter interval. The R15312HG30-460 also has a coalescing separator element that should be inspected at each oil change and replaced when differential pressure across the separator exceeds 8–10 PSI. Unlike a piston compressor where you're draining a crankcase every few months, rotary screw oil maintenance is hours-based, so logging runtime on your motor is the most reliable way to stay on schedule.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eHow loud is the R15312HG30-460 in a shop environment, and is it safe to run near work areas?\u003c\/h3\u003e\n\u003cp\u003eCast Air rotary screw units in this class typically operate at 68–72 dB(A) at one meter — significantly quieter than a comparable reciprocating piston compressor, which often runs 85–90 dB. That puts it well below OSHA's 8-hour TWA threshold of 90 dB, and in many shops it's quiet enough to carry a conversation nearby without shouting. If you have questions about installation placement or want to confirm specs for your specific facility layout, call us at \u003ca href=\"tel:866-217-0063\"\u003e866-217-0063\u003c\/a\u003e — we're Air Compressor Factory Direct, an authorized Cast Air dealer, and can help you spec the right setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the duty cycle on the R15312HG30-460, and how does that compare to a reciprocating piston compressor?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The R15312HG30-460 is rated for 100% continuous duty — it can run indefinitely without a mandatory cool-down period. A piston compressor typically runs at 60–75% duty cycle, meaning it needs to rest roughly 15–24 minutes out of every hour under sustained load. If your shop runs air tools, lifts, or spray equipment for extended shifts, the rotary screw design on this unit eliminates the production interruptions and heat buildup that come with reciprocating machines at that workload.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What CFM output does this unit produce, and what tools or equipment can it support simultaneously?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The R15312HG30-460 delivers approximately 50–54 CFM at 125 PSI from its 15 HP Cast Air rotary screw end. That output is sufficient to run multiple impact wrenches, a continuous-duty sandblast cabinet, plasma cutter air supply, or several DA sanders at the same time — depending on individual tool demand. For reference, a 1\/2 inch impact wrench typically draws 4–5 CFM, so this unit has enough headroom to serve a busy multi-bay shop or light production line without pressure drop issues.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What electrical service does the R15312HG30-460 require, and what breaker size do I need?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This unit runs on 460V, 3-phase power and draws approximately 21–23 FLA at that voltage. NEC requires a disconnect and breaker sized at 125% of FLA for motor branch circuits, so you'll want a 30-amp breaker minimum — verify with your electrician against your local code and actual wire run length. The 460V configuration is the most efficient option for 3-phase installs; it reduces current draw and allows smaller wire gauge compared to a 208\/230V 3-phase setup at the same horsepower.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What are the oil change intervals for the rotary screw end on this Cast Air unit?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Cast Air rotary screw compressors use compressor-grade synthetic lubricant with a typical service interval of 2,000–4,000 hours depending on operating environment — dusty or hot conditions call for the shorter interval. The R15312HG30-460 also has a coalescing separator element that should be inspected at each oil change and replaced when differential pressure across the separator exceeds 8–10 PSI. Unlike a piston compressor where you're draining a crankcase every few months, rotary screw oil maintenance is hours-based, so logging runtime on your motor is the most reliable way to stay on schedule.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How loud is the R15312HG30-460 in a shop environment, and is it safe to run near work areas?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Cast Air rotary screw units in this class typically operate at 68–72 dB(A) at one meter — significantly quieter than a comparable reciprocating piston compressor, which often runs 85–90 dB. That puts it well below OSHA's 8-hour TWA threshold of 90 dB, and in many shops it's quiet enough to carry a conversation nearby without shouting. If you have questions about installation placement or want to confirm specs for your specific facility layout, call Air Compressor Factory Direct at 866-217-0063 — we are an authorized Cast Air dealer and can help you spec the right setup.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/div\u003e","brand":"Cast Air","offers":[{"title":"Default Title","offer_id":53342577819861,"sku":"R15312HG30-460","price":26488.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/8466\/0949\/files\/Logo1_81e40d4d-3494-410f-935e-7fbfafe35fe4.webp?v=1772652825","url":"https:\/\/aircompressorfactorydirect.com\/products\/castair-15-hp-3phase-rotary-screw-air-compressor-58-cfm-at-100-psi-120-gal-horiz-tank-460-r15312hg30","provider":"Air Compressor Factory Direct","version":"1.0","type":"link"}